Description

Dry, Ready mix plaster with NO LIME for interior and exterior use.

It conforms to European Standards ΕΝ998-1 & ΕΝ998-2 specifications.

 

Advantages

  • Ready for application
  • Replace traditional plasters
  • Stable standardized properties
  • Excellent workability
  • High Adherence and resistance 

 

Product Identity    

  • Appearance: Grey cement-based powder    
  • Packaging: 25 kg bags    
  • Storage: 8 months in the original packaging and in a dry place      
  • Particle size: 0-2.5 mm  

Application Data    

  • Mixing Ratio: 25kg in 6-8L water     
  • Pot life: 1 hour at 23ºC and 50% RH    
  • Thickness: 25-30mm/coat    
  • Consumption:   - Plastering: 8-10 kg/m² depending on use and surface.

                                        - Brick Laying: 6-7 kg/ m² for 10cm masonry              

                                                                20 kg/ m² for 20cm masonry        

  • Application temperature: +5 ºC - +35 ºC

Plastering    

  • Allow 3-4 weeks after brick laying before plastering.    
  • Apply the 2nd hand at least one day after the 1st hand application.    
  • Apply the plaster on the prepared surface by spraying it or manually with a plastering trowel at a thickness between 10 and 30 mm in one layer. If more thickness is required, the application should be done in two layers. The 1st layer should be roughened then cured.    
  • Protect the newly applied plaster from sunshine and wind. The new plaster has to be cured with water for at least three days by spraying 3 to 4 times daily.  

Brick or block laying    

  • Bricks or blocks must be free of dust, at a temperature of +15 ºC - +25 ºC.    
  • PITTAKIS CEM is similar in application to conventional mortars.    
  • Joints between bricks should not exceed 10mm.  

Substrates Preparation    

  • The substrate must be solid, free of dust, loose parts and oils.   
  • To avoid immediate absorption of mix water by the substrate and for better adhesion saturate the surface to provide a saturated surface dry condition.  

Preparing the mix   

  • Pour the material into clean water and mix (mix in a concrete machine for big quantities or with a low speed electric mixer for small quantities) until a homogeneous lump free mix is obtained.   
  • Allow mixture settle for 5 minutes prior the application. Attention! Additional water will make your mixture sloppy and may cause negative results on final strength.    
  • Use the mixture when is still fresh. Do not leave the mix unmixed for a long time.    
  • Do not mix with water or latex additive when the mixture starts to set in the bucket. In such case the mix should be dropped.

To Find a Shop for this product, click here.